Sale!

Transcutaneous Jaundice Detector

135,000.00 105,000.00

Model Name:- Bili Check

Type:- Blood Testing Equipment

Brand Name:- Medisource

Model Number:-  MS1006

Packaging:-Aluminum box(inside); Paper Carton (outside)

It is well established that the transcutaneous measurement of bilirubin level is well correlated with serum concentration2,3,4.  The advantages to the healthcare professional and the patient of being able to determine bilirubin levels instantly and non-invasively are obvious.Portable transcutaneous jaundice meters offer a quick and easy method for dynamic and ongoing assessment to identify abnormal bilirubin levels. They are suitable for use in all clinical settings: NICU; SCBU; maternity; post-natal; and in the community.

3 in stock (can be backordered)

Compare

Description

Development Care Considerations:

It is well documented that neonates undergo numerous invasive procedures on a daily basis5; this not only causes unnecessary stress on the infant, but can also impact their long-term developmental care outcome. Using a transcutaneous jaundice meter dramatically reduces the need to take blood samples for hyperbilirubinemia testing; no painful needles is much kinder to babies.

The simplicity of operation and speed of obtaining readings with the  jaundice meter that Delta Medical supply makes repeated testing to measure efficacy of treatment possible, with minimal impact on the patient.  It is therefore practical to determine whether further intervention needs to be considered and to optimise patient care whilst following best developmental care principles. The reduction in neonatal stress and parental anxiety add to the process of optimising developmental care

Product Description:-

The Transcutaneous Jaundice Detector is a portable instrument which is mainly used in the dynamic clinical examination of neonatal jaundice.

The transcutaneous concentration of bilirubin correlative with serum bilirubin concentration can be determined instantly and non-invasively since the detector is placed on the neonatal skin. This prevents the neonates from any discomfort typically associated with abstraction of blood samples, reduces costs since test results are immediate, and increases the working efficiency of doctors and nurses.

The Transcutaneous Jaundice Detector is developed with advanced electronics and optics, adopting Fiber Optics, spectrum splitter, controlled spectrum filter, NFM switching, and information processing techniques.

Jaundice Detector Feature & Benefits:-

Jaundice meter is very simple to apply and operate, making it very quick and easy to obtain bilirubin readings with minimal disturbance to the baby. The compact ergonomic design makes it easy to hold, with a display that is easy to read, and very convenient to carry around. It is suitable for screening infants from 35 weeks’ gestation and automatically stores the last 20 readings for review if needed.

The advanced optical design and processing algorithms ensure highest accuracy. Self-calibration ensures accuracy and efficacy; the unit is supplied with an external calibration unit for periodic checks and adjustment; there is negligible maintenance required.

The unit is easily cleaned for infection control. The reduction in need for blood sampling gives further potential advantages in relation to infection prevention in addition to the developmental care considerations.

The portability and simplicity make the unit ideal for use in all areas, including routine post-natal care and community care. The jaundice meter can facilitate routine screening and accelerate appropriate care and treatment of babies who may have an elevated bilirubin level.

· Liquid Crystal Display is easily view able

· Streamlines design makes it small, delicate and easy to be handled.

· Long service life, low energy consumption

· Battery indicator indicates when battery needs recharging

· Test results are rapid providing serum bilirubin concentration

· Storage and memory function

· convenient to browse and delete functions

· convenient self calibration

· easy use and maintenance

Instructions Of Use:-

  • 1.  Transcutaneous Jaundice Detector is a portable instrument which is mainly used in the dynamic clinical examination of neonatal jaundice
  • 2. The transcutaneous concentration of bilirubin correlative with serum bilirubin concentration can be determined instantly and non-invasively since the detector is placed on the neonatal skin. This prevents the neonates from any discomfort typically associated with abstraction of blood samples, reduces costs since test results are immediate, and increases the working efficiency of doctors and nurses
  • 3. Transcutaneous Jaundice Detector is developed with advanced electronics and optics, adopting Fiber Optics, spectrum splitter, controlled spectrum filter, NFM switching, and information processing techniques.

Specification:-

Jaundice_Table_v1

Display LCD, 3 figures
Power AA 1.5V×2 batteries
Indicator light for ready Green
Measurement range 0.0mg/d L ~ 30.0 mg/d L
Measurement accuracy low + 1.0 mg/d L17umol/L, rest ±1.5 mg/d L±25.5 umol/L
Preparation time <12 seconds
Record function Memorize 20 latest measuring results and circularly reviews recorded data.
Reexamination rate <10%
Safety classification IEC60601-1 class I, type CF
Certificate CE/ ISO13485/GMP/IEC 62471

References

  1. National Institute for Health & Care Excellence (NICE). Clinical Guidance CG98: Jaundice in newborn babies under 28 days.  www.nice.org.uk, 2010
  2. American Academy of Pediatrics Subcommittee of hyperbilirubinemia. Management of hyperbilirubinemia in the newborn infant 35 or more weeks of gestation.  Pediatrics, 2004
  3. Holland, L., & Blick, K. Implementing and validating transcutaneous bilirubinometry for neonates.  AJCP, 2009.
  4. Najundaswamy, S, Petrova, A., et al. The accuracy of transcutaneous bilirubin measurements in neonates: a correlation study.  Neonate, 2004
  5. Carbajal, R., Rousset, A., Danan, C., et al. Epidemiology and treatment of painful procedures in neonates in intensive care units.  JAMA, 2008

Additional information

Weight 0.3 g
Dimensions 20 × 20 × 20 cm

Reviews

There are no reviews yet.

Be the first to review “Transcutaneous Jaundice Detector”

Your email address will not be published. Required fields are marked *

en_USEnglish
de_DE_formalGerman en_USEnglish